Phil,
I would say it is an acceptable practice. There is a lot of entrenched
rumor and myth from the very early days of ultrasonic cleaning, when the
frequencies and power levels used damaged bond wires in ICs. But modern
ultrasonic cleaners use frequencies and power levels know to be safe.
Doug Pauls
Principal Materials and Process Engineer
Rockwell Collins
On Fri, Aug 15, 2014 at 1:18 PM, Nutting, Phil <[log in to unmask]>
wrote:
> Is it a common or acceptable practice to use an ultrasonic cleaner to wash
> SMT circuit boards?
>
> Phil Nutting | HVP Development Engineer | Excelitas Technologies Corp
>
> Lab: +1 978.224.4332 | Office: +1 978.224.4152
> 35 Congress St, Salem, MA 01970 USA
> [log in to unmask]<mailto:[log in to unmask]>
> www.excelitas.com<http://www.excelitas.com/>
>
>
> [Description: Excelitas R_emailsig]
>
>
> Please consider the environment before printing this e-mail.
> ________________________________
> This email message and any attachments are confidential and proprietary to
> Excelitas Technologies Corp. If you are not the intended recipient of this
> message, please inform the sender by replying to this email or sending a
> message to the sender and destroy the message and any attachments. Thank
> you.
>
>
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud service.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________
>
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
|
|
|