Nickle is normally used between Gold and Copper to prevent the Gold from
spontaneously alloying with the Copper, and disappearing after a time.
You are apparently currently using ENIG...Electroless Nickle, with immersion
Gold...typically the Gold is less than 0.25 micron thick.
When the folks in the UK used to have a standard set by their telecom people
which allowed, or even specified (!!!!) Gold over Copper, the Gold needed to
be 1 micron + thick, to delay this alloying process.
ENIG, properly done, has nearly an infinite shelf life before it must be
soldered. Gold over Copper will have a finite shelf life, dependent on Gold
thickness.
Does this help?