Steve,
It may end up being one of life's little unexplained mysteries.
David A. Douthit
Manager
LoCan LLC
==========================
Steve Gregory wrote:
> Hi David! I guess the reason I call this strange, is because I've had
> rework performed on literally hundreds of these type of parts, with
> the heat sink in the top, and haven't seen this problem before. When I
> say hundreds, I refer to a situation where a part was installed on an
> assembly, don't want to name names, at three-per, and the assembly
> didn't work. The manufacturer of the device says there was no die
> change, but for some reason, earlier date-code parts worked fine. So
> we changed out all these parts....same design, heat-sink in the top,
> but never saw cracking like this. To emphasize, this was just one part
> that did this, but it was so strange...I had to share. -Steve Gregory-
>
> Steve,
>
> You might consider the fact that metal will change
> temperature much faster than polymers.
> This thermal gradient "split" can cause serious temporary
> CTE mismatches.
>
> David A. Douthit
> Manager
> LoCan LLC
>
> ---------------------------------------------------
> Technet Mail List provided as a free service by IPC using LISTSERV
> 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text
> in the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
> http://listserv.ipc.org/archives
> Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
> information, or contact Keach Sasamori at [log in to unmask] or
> 847-509-9700 ext.5315
> -----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|