Subject: | |
From: | |
Date: | Mon, 02 Dec 96 16:53:28 cst |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Hi Technet:
I am trying to revise our in-house qualification
specification for PWB Fabricators. I am eliminating all
references to MIL-P and MIL-STD documents and referring to
ANSI/IPC documents.
My question: Is IPC-RF-245 the document to refer to when
specifying Multilayer Flex product performance? It seems to
cover all of the issues that I would consider pertinent.
IPC-FC-250A covers single and double sided flex, but does
not cover M/L flex. If IPC-RF-245 (which is a rigid-flex
spec) is not the right spec, what is???
Thanks,
Dave Sullivan
Rockwell Collins, Inc.
[log in to unmask]
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
|
|
|