Has anyone seen any reliability data to show that Lead Free solders
would work better with rounded pads than with squared pads? This is not
to dispute Brian's contention (I actually agree with him). I was just
curious to see if any data supports this claim.
Lee Whiteman
Senior Manufacturing Engineer
American Competitiveness Institute
E-Mail: [log in to unmask]
Ph: (610) 362-1200 x208
Fax: (610) 362-1290
This message is for informational purposes only and does not supersede,
modify, or create any agreements with ACI. Information contained in this
message does not bind ACI or its affiliates to any commitment, either
express or implied, unless ratified in writing by an authorized
representative.
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Brian J. Toleno,
Ph.D.
Sent: Wednesday, March 24, 2004 1:29 PM
To: [log in to unmask]
Subject: Re: [TN] FW: Round SMT pads
Another reason for rounded pads is when using Pb-free solders, due to
the
increase in surface tension and wetting angle, people are moving to
rounded pads so that they don't have exposed corners after reflow.
Brian J. Toleno, Ph.D.
Sr. Applications Chemist
Loctite Electronics
15051 East Don Julian Rd
Industry, CA 91746
Ph: 626-968-6511 x304
Cell: 626-215-0879
**********************************************************************
This email and any files transmitted with it are confidential and
intended solely for the use of the individual or entity to whom they
are addressed. If you have received this email in error please notify
the system manager.
This footnote also confirms that this email message has been swept by
MIMEsweeper for the presence of computer viruses.
http://www.loctite.com/
**********************************************************************
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|