Subject: | |
From: | |
Reply To: | TechNet E-Mail Forum. |
Date: | Wed, 7 Apr 1999 07:50:00 -0400 |
Content-Type: | multipart/alternative |
Parts/Attachments: |
|
|
Try increasing your etch -rate, this will improve your surface. Also you
may want to increase your acid content in the Entek bath itself.
----------
> From: Michael D. Doty <[log in to unmask]>
> To: [log in to unmask]
> Subject: [TN] Entek question
> Date: Thursday, April 01, 1999 7:34 PM
>
> Hi Techies,
> I'm currently having a problem getting even coverage on a
> panel that has lots of smts and bgas. I run a dip process and have
> eliminated everything up to and including the entek as a problem.
All
> solutions have been changed and different methods of precleaning
have
> been tried. Short of conveyorized equipment is there anything that I
> can try so as to eliminate the spotty coverage.
>
> Thanks in advance,
>
> Mike Doty
>
> ################################################################
> TechNet E-Mail Forum provided as a free service by IPC using LISTSERV
1.8c
> ################################################################
> To subscribe/unsubscribe, send a message to [log in to unmask] with
following text in the body:
> To subscribe: SUBSCRIBE TechNet <your full name>
> To unsubscribe: SIGNOFF TechNet
> ################################################################
> Please visit IPC's web site (http://www.ipc.org) "On-Line Services"
section for additional information.
> For technical support contact Hugo Scaramuzza at [log in to unmask] or
847-509-9700 ext.312
> ################################################################
|
|
|