TECHNET Archives

1995

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Received:
by ipc.org (Smail3.1.28.1 #2) id m0tQhZp-0000PgC; Fri, 15 Dec 95 15:22 CST
Encoding:
17 TEXT
Old-Return-Path:
<miso!sequent.com!wallyd>
Date:
Fri, 15 Dec 95 11:01:00 PST
Precedence:
list
Resent-From:
Message-ID:
X-Status:
Status:
O
X-Mailing-List:
<[log in to unmask]> archive/latest/73
From [log in to unmask] Sat Apr 27 15:
30:23 1996
TO:
ComplianceNet <[log in to unmask]>, DesignerCouncil <[log in to unmask]>, TechNet-request <[log in to unmask]>, TechNet <[log in to unmask]>
Return-Path:
Resent-Message-ID:
<"qzMDk3.0.QQB.mRUqm"@ipc>
Subject:
From:
"Wally Doeling (wallyd)" <[log in to unmask]>
Resent-Sender:
X-Loop:
X-Mailer:
Microsoft Mail V3.0
Cc:
"Wally Doeling (wallyd)" <[log in to unmask]>
Parts/Attachments:
text/plain (20 lines)

     The overall question is how to calculate the current carrying capacity 
of a thermal relief.

     IPC - D-275  indicates that the total area of the thermal ties should 
be used to calculate the current.
     However, the  chart on page 10, to calculate current capacity of a line 
makes a assumption that this is
     a long free line.

     Since the thermal ties are very short (.010) and tied to a plane.  This 
adds a lot of heat-sink and it looks to me like this
     needs to be taken into account when calculating current capacity.

     Any experience out there with this problem?

 ----------