TECHNET Archives

1996

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Gita Khadem" <[log in to unmask]>
Date:
Tue, 30 Apr 96 11:18:07 CST
Content-Type:
text/plain
Parts/Attachments:
text/plain (26 lines)
     Gary,
     Are you looking for PWB fabrication process points or PWA assembly?
     Looking at PWA assembly criteria, One thing you need to keep in mind 
     is that, more copper means more heath sinking at soldering so you need 
     to pay attention to the connections and implement proper thermal 
     relief patterns.
     [log in to unmask] 


______________________________ Reply Separator _________________________________
Subject: copper thickness
Author:  [log in to unmask] at Dell_UNIX
Date:    4/30/96 05:50 AM


Would like input on the subject of 1 oz. vs. 2 oz copper thickness on inner 
layers. What types of end products would be affected if 1 oz. were 
substituted for 2 oz? What design considerations are most critical? Is it 
safe to say that 1 oz. vs. 2 oz. should no longer be an issue? 
Thank you for input.
Gary Longman
Electropac
     