HI All,
I agree with Richard.
The site for the "Temprobe" is:
http://www.saunderstech.com/
Thanx
Bill Butman
--- "Elensky, Richard" <[log in to unmask]> wrote:
> Unless it is a customer requirement to provide
> thermal profiles for each
> lot, I don't understand the necessity to profile so
> frequently. Generally
> speaking, I have always used just a few profiles for
> everything. These were
> defined for different pastes or epoxies. As a new
> product came to the shop
> floor, I would run a sample with the Datapaq to
> confirm the appropriate
> thermal conditions and add that assembly to the list
> of assemblies used on
> that profile.
>
> Regarding the attachment issue, I would suggest the
> Sanders thermocouples
> that clamp onto the edge of the board (Sold by ECD
> 1-800-323-4528 or Datapaq
> 508-988-9000) They are very accurate and require no
> attachment to the
> device (solder, glue, tape). I had my set (8", 10",
> and 12") for several
> years and used them for both reflow and wave solder
> applications, proving
> they were quite robust.
>
> Hope this helps,
>
> Rich
>
> Richard Elensky
> Sr. Manufacturing Engineer
> [log in to unmask] <mailto:[log in to unmask]>
>
> Tel: 559-292-1111 x246
> Fax: 559-292-9355
>
> Dantel
> 2991 North Argyle Ave.
> Fresno, CA, 93727
> Visit our web site at:
> http:// www.dantel.com <http://www.dantel.com>
>
>
> ----------
> From: Brad A. Smith
> [SMTP:[log in to unmask]]
> Sent: Thursday, October 25, 2001 8:37 AM
> To: [log in to unmask]
> Subject: [TN] Reflow profiling
>
> Hello All,
>
> I am with a low volume, frequent changeover
> contract manufacturer.
> We are
> trying to implement a system where we
> profile the first assembly of
> every
> new run through our reflow oven. We are
> currently using high
> temperature
> solder for profiling. If we start to use the
> high temp solder for
> this, we
> will have to scrap the assemblies. Does
> anyone have any suggestions
> for
> alternatives to high temp solder? Any
> suggestions would be greatly
> appreciated.
>
> Thank you,
> Brad Smith
> Process Technician
> Badger Electronics Co., Inc.
> (262)886-8800
> [log in to unmask]
>
>
>
----------------------------------------------------------------------------
> -----
> Technet Mail List provided as a free service
> by IPC using LISTSERV
> 1.8d
> To unsubscribe, send a message to
> [log in to unmask] with following
> text in
> the BODY (NOT the subject field): SIGNOFF
> Technet
> To temporarily halt delivery of Technet send
> the following message:
> SET Technet NOMAIL
> Search previous postings at: www.ipc.org >
> On-Line Resources &
> Databases > E-mail Archives
> Please visit IPC web site
> (http://www.ipc.org/html/forum.htm) for
> additional
> information, or contact Keach Sasamori at
> [log in to unmask] or
> 847-509-9700 ext.5315
>
>
----------------------------------------------------------------------------
> -----
>
>
---------------------------------------------------------------------------------
> Technet Mail List provided as a free service by IPC
> using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask]
> with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send the
> following message: SET Technet NOMAIL
> Search previous postings at: www.ipc.org > On-Line
> Resources & Databases > E-mail Archives
> Please visit IPC web site
> (http://www.ipc.org/html/forum.htm) for additional
> information, or contact Keach Sasamori at
> [log in to unmask] or 847-509-9700 ext.5315
>
---------------------------------------------------------------------------------
=====
Bill Butman
Circuit Technology Center
45 Research Drive
Haverhill, MA 01832
__________________________________________________
Do You Yahoo!?
Make a great connection at Yahoo! Personals.
http://personals.yahoo.com
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
|