Technet,
After recieving a copy of the Jedec Standard, J-STD-020, I have a question
that hopefully one of you might answer. The Convection Reflow profile
requirement is listed as:
Ramp up rate: +6 degrees C/sec. max
Temperature maintained at 125 degrees C (+/-25): 120 seconds maximum
Temperature maintained above 183 degrees C: 120 - 180 seconds
Time at maximum temperature: 10 - 40 degrees C
Maximum temperature: 220 degrees C (+5/-0)
Ramp down rate -6 degrees C/sec max
My question is when figuring the time maintained at 125 degrees should one
only be counting the time actually maintained at 125 degrees or should I
include time between 100 and 150 degrees C?
Thanks,
Brian
ETS, LLC - West ETS, Inc. - East
3939 N. Freya St. PO Box 47887
Spokane, WA 99207 Plymouth, MN 55447
509-483-0900 (voice) 612-553-0051 (voice)
509-483-0331 (fax) 612-553-0246 (fax)
[log in to unmask] [log in to unmask]
Benefit from a direct relationship with the manufacturer!
################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe: SUBSCRIBE TechNet <your full name>
To unsubscribe: SIGNOFF TechNet
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################
################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe: SUBSCRIBE TechNet <your full name>
To unsubscribe: SIGNOFF TechNet
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################
|
|
|