dash 13 is not a slash sheet 25 resin. dash 13 is slash sheet 26 I believe.
Tim Reeves
-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Eddie Rocha
Sent: Wednesday, February 25, 2004 10:50 AM
Subject: Re: IPC-4101 Material
I've used Nelco's (-13) as an alternate to Getek. Allied Signal's (now
Isola)
FR408 is another alternative .
thanks,
On 25 Feb 2004 at 10:41, Marsico, James wrote:
Good day...
Our designers want to use an FR-4 material which is designated as
IPC-4101/25. The /25 material has a permittivity of 4.4, while the
other
FR-4 materials (/21and /24) are listed as 5.4. I found out that
GETEK is
classified as /25, and was wondering if this is the only /25 material
available. Is there a generic (or product) name for the /25 material?
The
slash sheets in 4101 have a maximum permittivity at 1 Mhz, do the
graphs
exist that show the Dk at various frequencies?
Jim Marsico
Senior Engineer
Production Engineering
EDO Electronics Systems Group
[log in to unmask] <mailto:[log in to unmask]>
631-595-5879
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV
1.8e
To unsubscribe, send a message to [log in to unmask] with
following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-
509-9700 ext.5315
-----------------------------------------------------
-- Thanks,
Eddie Rocha
(408) 978-8992 x 282
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|