Hi Eric,
Be careful with product that may see autoclaving; I have worked with a client
with an implant product where autoclaving in followed by product flexing
inside the stomach cavity prematurely destroyed the solder joints. Also do not
count on all autoclaves to run on only 121C. Your potential for trouble will
depend on your design details of your product.
Werner Engelmaier
Engelmaier Associates, L.C.
Electronic Packaging, Interconnection and Reliability Consulting
7 Jasmine Run
Ormond Beach, FL 32174 USA
Phone: 904-437-8747, Fax: 904-437-8737
E-mail: [log in to unmask]
################################################################