Subject: | |
From: | |
Reply To: | |
Date: | Thu, 26 Feb 2015 14:54:50 +0000 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
If you are taking guesses - mine is 'no'.
The difference is just purity, right? But I'm not sure that you care too much about purity in a He leak test - impurities shouldn't prevent any leaking.
Ben
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of David Hillman
Sent: Wednesday, February 25, 2015 7:06 PM
To: [log in to unmask]
Subject: EXTERNAL: [TN] Helium Quality Test Influence Question
Hi gang - hey, need some quick assistance. Does anyone know if using "commercial" grade He instead of "analytical" grade He would cause an issue in helium leak testing? I think I know the answer but looking for a sanity check.
Dave Hillman
Rockwell Collins
[log in to unmask]
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
|
|
|