TECHNET Archives

1996

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Todd Rogers" <[log in to unmask]>
Date:
Fri, 9 Aug 1996 10:23:53 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (17 lines)
We are attempting to switch our pre-clean process prior to soldermask from
chem-clean followed by a mechanical scrub to chem-clean only.  We have
experienced problems with poor soldermask adhesion at the nickel/gold tab
area.  We are using a reverse current tin/lead strip prior to nickel/gold
and the HCL seems to be getting under the mask causing it to peel.  Has
anyone else had experience with a chem-clean process prior to soldermask
and reverse current plate prior to nickel/gold.

***************************************************************************