We are attempting to switch our pre-clean process prior to soldermask from
chem-clean followed by a mechanical scrub to chem-clean only. We have
experienced problems with poor soldermask adhesion at the nickel/gold tab
area. We are using a reverse current tin/lead strip prior to nickel/gold
and the HCL seems to be getting under the mask causing it to peel. Has
anyone else had experience with a chem-clean process prior to soldermask
and reverse current plate prior to nickel/gold.
***************************************************************************