Hi Drew,
Please correct me if I'm wrong. Are you saying that it could be a layer
of gold in between the layer of intermetallics and E-Ni? I would have a
hard time imagining it as a layer of immersion gold is very thin (o.1 or
less micron) and it gets dissolved in solder, so a layer of Ni-Sn
intermetallics can be formed (some authors say it's in fact Ni/Sn/Au
intermetallics). I've never heard of a layer of NI-Sn intermetallics
sitting on a layer of gold.
Regards,
Vladimir
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Drew meyer
Sent: Monday, February 25, 2008 11:24 AM
To: [log in to unmask]
Subject: Re: [TN] Metallurgists, need assistance, closing this one
Phil,
I'm going to go out on a limb here. We have witnessed something like
this
three seperated times now from three different board houses.
What we experienced follows this process. The board house decides that
something associated with the plating on several panels is not right.
They
removed the gold and start over. The problem is that they are not
completely
successful removing the gold. You form a solder joint to the nickel
layer but
beneath that layer is a layer of gold. The nickel bond to the gold is
very weak.
If you have access to a SEM(Scanning Electron Microscope) that has EDS
(Electron Dispersive Spectroscopy) you can neatly locate and plot the
extra
layer or remnants of gold present.
Not sure it this is true in your case but it can happen and has happened
to
us.
It is truly a nightmare as the board house often does not keep detailed
records
of which panels and which subsquent boards could be affected. This
leaves
the entire lot in question unless you can locate all the boards by the
number
of panels affected.
This what we were forced to do with finished product in one case.
Drew
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|