Subject: | |
From: | |
Reply To: | TechNet E-Mail Forum. |
Date: | Wed, 15 Mar 2000 08:07:24 -0600 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Yes, if your master is designed at 6 mil, your vendor can have overall width down to 4.8 mils and isolated reductions down to 3.8 mils. If this will affect function, you need to specify a 6 mil minimum on your drawing. Your vendor will hopefully ask to increase their production artwork.
>>> [log in to unmask] 03/14/00 04:27pm >>>
It's a good question, I think you just misunderstood it.
Say I design a board with 6 mil minimum traces,
but I have routed the IC power at 10mils.
Is anyone saying I should accept 20% less than 6mils on those traces?
I don't think so....
-----Original Message-----
From: Howieson, Rick [mailto:[log in to unmask]]
What part of the minimum value is misunderstood? If the
requirement
states minimum 10 mils WHY are you making it 11???
Rick
>-----Original Message-----
>From: Franklin Asbell [SMTP:[log in to unmask]]
>
>Keep in mind how that is worded. The requirement say's
"...20% of the
>minimum value, or less."
>
>Now if the artwork require a minimum trace width of let's
say 10 mils, and
>you make the trace 11 mils, the 11 mils trace is reduce by
21%, would this
>be rejectable in accordance with A-600? Or would the
minimum value (i.e. 10
>mils plus or minus the allowable tolerance) be the starting
point to
>subtract 20%?
##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe: SUBSCRIBE TECHNET <your full name>
To unsubscribe: SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
##############################################################
##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe: SUBSCRIBE TECHNET <your full name>
To unsubscribe: SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Keach Sasamori at [log in to unmask] or