TECHNET Archives

1996

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Eltek Ltd. - Process Engineering" <[log in to unmask]>
Date:
Tue, 17 Dec 1996 17:25:13 +0200 (IST)
Content-Type:
text/plain
Parts/Attachments:
text/plain (28 lines)
Hi Technets ! 
Recently we have some problems with 0.3 mm ( 12 mills) via holes drilled
through 14 layers MLB , 2.4 mm (0.094" ) thick boards. Based on
microsections we found, that 2-3 holes per total count of 14000 are
partially clogged causing disturbance for PTH.It seems,that the source is in
drilling.We have not ultrasonic tank for  cleaning . We are considering two
actions :
1)pack drilling
2)high pressure rinse (300 psi)
Does anyone has suggestions for immidiate action and for the future ?
Szpruch Edward
Eltek Ltd - Israel
Tel  972 3 9395050
Fax 972 3 9309581
E-mail :  [log in to unmask]

***************************************************************************