Does this standard address the baking of flexible printed circuits prior to
assembly?
I am interested in any information available on this subject.
Thanks
Debbie Kenney
Engineer
M-Flex / AMT
Direct (714) 688-5242
Fax (714) 996-3834
[log in to unmask]
> -----Original Message-----
> From: Francois Monette [SMTP:[log in to unmask]]
> Sent: Friday, June 21, 2002 6:50 AM
> To: [log in to unmask]
> Subject: [TN] Moisture sensitive device
>
> Hi Marki,
>
> I don't think that anyone has answered your question yet, so here it is :
>
> The proper bake conditions, along with other handling guidelines for
> moisture-sensitive devices are all documented in J-STD-033, a joint
> IPC/JEDEC standard. The standard does not address vaccum bake but it
> includes a table for simple temprature bake cycles at 40C for components
> in
> reels and 125C for components in trays. The actual duration varies based
> on
> the MS level of the component and its body thickness.
>
> The default bake cycle for components in reels is 68 days at 40C. (yes 68
> days as in two months). Most assemblers cannot live with this kind of
> cycle
> time so the solution is to remove all components from the reel, bake them
> at
> 125C and then re-tape them or use them in JEDEC trays. The default cycle
> time at 125C is 48 hours. I am aware that some people use a combination of
> vaccum and temperature to reduce the bake duration and I can provide you
> with some technical articles and oven suppliers if you are interested.
>
> Regards,
>
> Francois Monette
> Cogiscan Inc.
> Tel : 450-534-2644
> Fax : 450-534-0092
> [log in to unmask]
> www.cogiscan.com
>
>
> Date: Tue, 18 Jun 2002 09:37:43 +0200
> From: Marki Sasportas <[log in to unmask]>
> Subject: Moisture sensitive device
>
> Hi Technos,
>
> Can someone tell me at what conditions (Vacuum&Temperture) should I dry
> those components which are
> packed in reel.
>
> Thanks in advance,
> Marki Sasportas.
>
> --------------------------------------------------------------------------
> -------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send e-mail to [log in to unmask]:
> SET Technet NOMAIL
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> ext.5315
> --------------------------------------------------------------------------
> -------
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
|
|
|