Doug Brooks wrote:
>
> Various sources (e.g. IPC) have formulas for propagation
> delay for microstrip and stripline configurations. Does
> anyone know of a formula for propagation time in a
> DUAL stripline configuration? Or is the stripline
> configuration close enough?
Hi Doug,
I have calculated prop delay in a round about manner.
I'll reference you to a Motorola ECL Design Apps book
they published a while ago.
In it prop delay is given as pd = (L*C)^0.5
L = inductance of the trace/inch (or whatever)
C = capacitance of the trace/inch ( " )
I use *any* calculation I can get my hands on to
get the C. L is a function of the trace itself.
Typically about 20 nH/inch.
I then drop these values into pd = (L*C)^0.5
for a prop/inch number, then simply multiply
by the length of the trace for total delay.
If this all sounds like flying by the seat of
my pants, I agree. But, I would challange
anyone to give me a reasonably accurate
measure of trace inductance to 3 decimal places.
I could be well wrong, so I would appreciate any ideas.
Regards,
Doug
************************************************************
------------------------------------------------------------
The comments and opinions stated herein are mine alone,
and do not reflect those of my employer.
------------------------------------------------------------
************************************************************
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
|
|
|