Subject: | |
From: | |
Date: | Tue, 23 Apr 1996 10:10:30 -0400 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
The minimum spacing on external surfaces is .005 inch ( for 0 to 100 V).
However, beyond min. spacing, other requirements have to be observed like no
residual copper between conductors and no ionic contamination to prevent
growth of Conductive Anodic Filaments (CAF).
|
|
|