     <<Most debur machines that I'm familiar with have high pressure and if 
     that isn't working properly it will push the burr down into the hole 
     but the water spray is not enough to "blow" the burr out through the 
     bottom of the hole/panel.>>
     
     I think that it would be good to define the "high" pressure.  I have 
     seen people call 150-200 psi as high, but I have also seen machines 
     with double that pressure.
     
     Matt Byrne
     
     
______________________________ Reply Separator _________________________________
Subject: Re: FAB: hole burrs
Author:  [log in to unmask] at Internet 
Date:    12/12/96 11:56 AM
     
     
It started maybe 5 to 6 months ago.
     
     
     
>______________________________ Reply Separator 
_________________________________
>     Has this problem just started recently or has it been an ongoing 
>     problem for some length of time?
>     
>     
>     Terry Pearo
>     Marcel Electronics
>
>
>______________________________ Reply Separator 
_________________________________
>Subject: FAB: hole burrs
>Author:  [log in to unmask] at Internet 
>Date:    12/11/96 2:55 PM
>
>
>We are experiencing sporadic instances of copper burrs after deburring.  It 
>appears that the deburr brushes are "shaving" burrs and almost but not quite 
>removing them.  Describing the condition as a burr may be misleading because 
>most people think of a burr as protruded copper.  These burrs exist when the 
>surface is 100% smooth and free of surface burrs after drill . What is left 
>is a curl of copper protruding the hole. What we have observed and done so far:
>     
>-When it happens, it is on the whole job-maybe a 2 panel run, maybe a 100 
>panel run.
>     
>-it occurs on multilayer and double sided panels. 
>     
>-it happens on .5 ounce through 2 ounce foils. 
>     
>-we have tried every combination of brushes.  320 grit works as well as 
>anything else. (The deburr machine has 2 brushes top, 2 brushes bottom.  The 
>operators are performing brush footprint checks several times a day.
>     
>-it appears to be on the top side of the panel as it is drilled. We have had 
>our drill tool supplier in (inconclusive)and have emphasized the obvious to 
>the drill operators-clean between panel stacks, make sure depth is correct, 
etc.
>     
>Any ideas?
>     
>thanks,
>     
>Lyle Anderson
>[log in to unmask]
     
*************************************************************************** 
* TechNet mail list is provided as a service by IPC using SmartList v3.05 * 
*************************************************************************** 
* To unsubscribe from this list at any time, send a message to:           * 
* [log in to unmask] with <subject: unsubscribe> and no text.        * 
*************************************************************************** 
* If you are having a problem with the IPC TechNet forum please contact   * 
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask]      * 
***************************************************************************
     
     
*************************************************************************** 
* TechNet mail list is provided as a service by IPC using SmartList v3.05 * 
*************************************************************************** 
* To unsubscribe from this list at any time, send a message to:           * 
* [log in to unmask] with <subject: unsubscribe> and no text.        * 
*************************************************************************** 
* If you are having a problem with the IPC TechNet forum please contact   * 
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask]      * 
***************************************************************************
     

***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to:           *
* [log in to unmask] with <subject: unsubscribe> and no text.        *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact   *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask]      *
***************************************************************************



ATOM RSS1 RSS2