Sender: |
|
X-To: |
|
Date: |
Tue, 27 Jul 2004 07:21:29 -0400 |
Reply-To: |
|
Subject: |
|
MIME-Version: |
1.0 |
Content-Transfer-Encoding: |
quoted-printable |
Content-Type: |
text/plain; charset="us-ascii" |
From: |
|
Parts/Attachments: |
|
|
Remove them - they will effect the drill wear and the lam bond. A resin
to resin bond is the strongest (drill interface to a land is the
weakest) and non-functional should be removed. On thicker PCB's, it is
GMP to have non-functional inner board thieving to support good resin
flow, package stability and eliminate low pressure areas. Most CAM
automations support a good logic for inner board thief.
Jeffrey Bush
Director, Quality Assurance and Technical Support
76 Technology Drive - POB 1890
Brattleboro, Vermont 05302-1890
Tel. 802.257.4571.21 Fax. 802.257.0011
[log in to unmask]
http://www.vtcircuits.com
-----Original Message-----
From: Ofer Cohen [mailto:[log in to unmask]]
Sent: Tuesday, July 27, 2004 6:48 AM
To: [log in to unmask]
Subject: [TN] Removal of non functional pads
Technetters,
Are there any guidelines regarding removal of non functional pads in
thick (>2.5 mm) PCBs? Are the guidelines documented somewhere?
Regards
Ofer Cohen
Manager
Quality Assurance, Reliability and Production Technologies
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|