Subject: | |
From: | |
Date: | Wed, 27 Nov 1996 07:13:01 +0800 (SST) |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
At 04:03 PM 11/26/96 -0800, you wrote:
>Hello Technetters!
>
>We have some boards where we have to use a no-clean flux in the
>THT process. Today we are haveing problem with thease boards
>in the In Circuits Test where we don't have any neadle acces beacuse
>of the flux resiudals after wave soldering.
>Today we are using Hollis PT500 with Hollis ultra spray station and
>Lonco 23F flux.
>We are now looking at some new flux and I want to here if some of
>you have hade the same problem and how you solved it.
-------------------- Reply --------------------------------------------
Hi,
Try Interflux IF2000.. It might help.
+====================================+
Kong Hui Poh
Process/Equipment Engineering Advisor..
Techgate Electronics
Email: [log in to unmask]
=-=-=-=-=-= -=-=-=-.=.=.=.=.=.=.=.=.=.=.=.=. =.=.=.
***************************************************************************