TECHNET Archives

1995

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Received:
by ipc.org (Smail3.1.28.1 #2) id m0tRtkt-0000M9C; Mon, 18 Dec 95 22:34 CST
Old-Return-Path:
Date:
Mon, 18 Dec 1995 23:37:19 EST
Precedence:
list
Resent-From:
Resent-Sender:
X-Status:
Status:
O
X-Mailing-List:
<[log in to unmask]> archive/latest/459
From [log in to unmask] Sat Apr 27 15:
31:35 1996
TO:
Return-Path:
Resent-Message-ID:
<"9Gno3.0.zz7.F3arm"@ipc>
Subject:
From:
[log in to unmask] (MR MIKE V CARANO)
X-Loop:
X-Mailer:
PRODIGY Services Company Internet mailer [PIM 3.2-334.50]
Message-Id:
Parts/Attachments:
text/plain (37 lines)
-- [ From: michael carano * EMC.Ver #2.10P ] --


------- FORWARD, Original message follows -------

> Date: Monday, 18-Dec-95 10:21 PM
> 
> From: michael carano           \ PRODIGY:     (GNTB07A)
> To:   ipc                      \ Internet:    ([log in to unmask])
> 
> Subject: plated thru hole rim voids
> 
> There are a few reasons for the problem that you have described. One
> possibility is that there is too much pressure applied if the booards
are
> being scrubbed prior to dry film lamination. The other possibility is
that
> there was no catalyst in that area and thus no electroless copper
> iniation. 
> What type of electroless are you using? Or are you employing a direct
> metallization process? There are several different types of DM
processes
> on the market and it is a possibility that the problem is here.
> Also, what hole size is common for the rim void? When do you see the
rim
> void? After electroless? After electroplating? After etching?
> E-mail me back with some details of your process or call 1-800-321-
9050
> and ask for Mike Carano