I think the information you are looking for is covered in
IPC/WHMA-A-620, Section 4.8.2
You are referring to a SINGLE turn on a pin which is presumably then
soldered into place as opposed to 5 turns of a 30 AWG wire on a square
pin which would then be a "solderless wire wrap termination".
Hope this helps.
Phil Nutting
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Crepeau, Phil (Space
Technology)
Sent: Wednesday, May 04, 2005 1:25 PM
To: [log in to unmask]
Subject: Re: [TN] Wire wrap
hi. i'm a little confused. your subject is 'wire wrap' which is a
solderless connection. where is the solder coming from that you are
referring to.
phil
-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Bob Arciolla
Sent: Wednesday, May 04, 2005 10:16 AM
To: [log in to unmask]
Subject: [TN] Wire wrap
Good Afternoon,
Is there any requirement for the amount of solder needed to be
acceptable around a pin that has one turn of wire around it. Is this
listed in IPC.
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------
Thanks, Bob Arciolla
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|