23/50 = 10.3 g/m3
5C @ 10.3g/m3 = 151%RH
5/50 = 3.4 g/m3
I've never tried, but it looks like you should be able to measure 5/50 using capacitive elements, however 5/37 = frozen wet bulb. Frost point at 5/50 is -4. It is rather unlikely you could produce such a wet & cold environment, so they probably figure it isn't worth the cost to monitor.
But I have no idea how they performed the sorption studies to come-up with the rules.
Chris
Chris Mahanna
Robisan Lab
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of colin mcvean
Sent: Monday, August 22, 2011 1:52 AM
To: [log in to unmask]
Subject: [TN] Prepreg storage conditions
Dear all,
"Simple" question regarding prepreg storage conditions.....
IPC4101 states that prepregs has shelf life of 6 months while in condition 1 at <5 Degrees C (41 F) and 3 months while in condition 2 at <23 Degrees C (73F) and <50% Rh.
Condition 1 does not clearly state a humidity control.
Does Humidity still have to be less than 50% while under condition 1? or is this a given considering Temperature vs. Humidity relationship
rgds
Colin
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|