Got to agree with Brian's' sentiments here.

If you're being told your VOC-free process is a fire hazard then it's
doubtful it's VOC-free or, your insurance/fire inspectors leave a lot to be
desired. Though I suppose in certain circumstances with a spray system there
could be an explosion risk.

Could it be your process is low-VOC and not VOC-free?

Although these terms are frequently used and switched around as though they
mean the same they are definitely not the same thing.

Best regards,

Andrew Hoggan
BBA Associates Ltd
www.bba-associates.com

-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Brian Ellis
Sent: 05 October 2001 09:45
To: [log in to unmask]
Subject: Re: [TN] Setting up conformal coating process


Dave

Excuse me, a water spray without VOCs (and all flammable liquids are
VOCs, by definition) is a fire hazard????????????????????????? Wow, I'd
better put sprinklers in over my garden irrigation system, oh! but what
liquid can I use in the sprinklers?

Brian

David Fish wrote:
>
> Hi Graham.
>
> Not commenting on the newer formulations that Graham references, the over
> spray of most water based, VOC free coatings is a fire hazard, according
to
> our insurance and fire inspectors.
>
> Dave Fish
> ----- Original Message -----
> From: "Graham Naisbitt" <[log in to unmask]>
> To: <[log in to unmask]>
> Sent: Thursday, October 04, 2001 5:00 AM
> Subject: Re: [TN] Setting up conformal coating process
>
> > Peter and others
> >
> > You should be aware that there are new developments in coating materials
> > that render your set-up much simpler and less expensive. These are water
> > based coatings, VOC free and MIL-Spec qualified. They are repairable and
> > fast to cure - <30 minutes at room temp.
> >
> > Dave Fish (hello Dave) gave you the correct info regarding various
issues
> > when dealing with conventional solvent based coatings. However, with
these
> > new water based materials: there are no special fire precautions - the
> fume
> > extraction isn't mandatory - your insurance costs will diminish,
> > significantly - the health & safety of your operators is improved.
> >
> > If you or anyone else wants more details contact me of-line.
> >
> > Regards, Graham Naisbitt
> >
> > [log in to unmask]
> > www.concoat.co.uk <http://www.concoat.co.uk>
> >
> > For instant access to Product Data Sheets register on the Tech-Shot area
> of
> > http:// www.concoat.co.uk <http://www.concoat.co.uk>
> >
> > Concoat Limited
> > Alasan House, Albany Park
> > CAMBERLEY GU16 7PH UK
> > Phone: +44 (0)1276 691100
> > Fax: +44 (0)1276 691227
> > Mobile: +44 (0)79 6858 2121
> >
> > Attention: This message is for the named person's use only. It may
contain
> > confidential, proprietary or legally privileged information. No
> > confidentiality or privilege is waived or lost by any mistransmission.
If
> > you receive this message in error, please immediately delete it and all
> > copies of it from your system, destroy any hard copies of it securely
and
> > notify the sender. You must not, directly or indirectly, use, disclose,
> > distribute, print, or copy any part of this message if you are not the
> > intended recipient. Concoat Ltd and any of its subsidiaries each reserve
> the
> > right to monitor all e-mail communications through its networks.
> >
> > Any views expressed in this message are those of the individual sender,
> > except where the message states otherwise and the sender is authorised
to
> > state them to be the views of Concoat Ltd or one of its subsidiaries.
> >
> > Although this message has been scanned for known viruses and
inappropriate
> > content, we recommend that recipients employ appropriate measures on
their
> > systems to intercept any such material.
> >
> > Thank You - Concoat Ltd
> >
> >
> >
> > -----Original Message-----
> > From: TechNet [mailto:[log in to unmask]]On Behalf Of peter lee
> > Sent: Friday, September 28, 2001 04:57
> > To: [log in to unmask]
> > Subject: [TN] Setting up conformal coating process
> >
> >
> > Hello,
> >
> > I like to hear your thoughts or experiences on setting
> > up a safe and efficient (in particular exhaust,
> > floorinconformal coating process g, ESD concerns,
> > layout, material storage). Please comment on anything
> > you feel critical to process control and success.
> >
> >
> > Peter
> >
> >
> > __________________________________________________
> > Do You Yahoo!?
> > Listen to your Yahoo! Mail messages from any phone.
> > http://phone.yahoo.com
> >
>
> --------------------------------------------------------------------------
> --
> > -----
> > Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> > To unsubscribe, send a message to [log in to unmask] with following text
in
> > the BODY (NOT the subject field): SIGNOFF Technet
> > To temporarily halt delivery of Technet send the following message: SET
> > Technet NOMAIL
> > Search previous postings at: www.ipc.org > On-Line Resources & Databases
>
> > E-mail Archives
> > Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
> additional
> > information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> > ext.5315
>
> --------------------------------------------------------------------------
> --
> > -----
> >
>
> --------------------------------------------------------------------------
> -------
> > Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> > To unsubscribe, send a message to [log in to unmask] with following text
in
> > the BODY (NOT the subject field): SIGNOFF Technet
> > To temporarily halt delivery of Technet send the following message: SET
> Technet NOMAIL
> > Search previous postings at: www.ipc.org > On-Line Resources & Databases
>
> E-mail Archives
> > Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
> additional
> > information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> ext.5315
>
> --------------------------------------------------------------------------
> -------
> >
>
> --------------------------------------------------------------------------
-------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send the following message: SET
Technet NOMAIL
> Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
> Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
> --------------------------------------------------------------------------
-------

----------------------------------------------------------------------------
-----
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET
Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
----------------------------------------------------------------------------
-----

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2