Hi Ken:
We would suggest to clean the board prior to conformal coating.
For a current client we have to clean the no-clean (SAC305) prior to parylene coating. This promotes adhesion and prevents voids from forming.
Regards
Bob Wettermann
BEST Inc
--- On Thu, 3/4/10, Ken Bloomquist <[log in to unmask]> wrote:
From: Ken Bloomquist <[log in to unmask]>
Subject: [TN] Conformal Coat Over No-Clean Flux
To: [log in to unmask]
Date: Thursday, March 4, 2010, 11:20 AM
We have a twelve leaded, through-hole component that has to be hand soldered
on the circuit board. The assembly gets conformal coated with urethane. We
would like to hand solder these twelve leads using no-clean and then
conformal coat the board. The component would be added as a final step after
the assembly has first been cleaned.
Since this is not a "total no-clean" process do you see any issues applying
conformal coat over these twelve no-clean solder joints?
Best regards,
KennyB
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|