I am considering to switch the plating used on our PCB's from HASL to
gold immersion. The reason I am considering making this change is to
improve the solder joint reliability of our 20mil components.
My company is a manufacture of RF products from 300MHz to 2.4GHz. When I
switch to gold immersion plating is there any electrical characteristics
I should be concerned about between gold immersion and HASL. Is there
any types of testing I should do to verify I did not change the
performance of my products.
Any information would be helpful.