Hi Michael,
In my experience it is not needed to re-bake PCB's after cleaning.
Even when you soak a PCB in a bucket filled with water, it takes hours until the board has absorbed enough moisture to result in delamination-problems.
This may not be true for polyimide or other sensitive materials, but for standard FR4 I wouldn't worry.
Kind regards,
Daan Terstegge
SMT Centre
Thales Communications
Unclassified mail
Personal Website: http://www.smtinfo.net
>>> Michael Bell <[log in to unmask]> 10/03 9:49 pm >>>
What is the impact on a PCB if an operator has ultrasonically clean a PCB in
IPA. The PCB was cleaned for about 5minutes after the paste had been
scrapped off. Would the PCB absorb the IPA and in-turn lead to delamination
or have any other degrading effect?
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
|
|
|