TECHNET Archives

February 2018

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Sender:
X-To:
Date:
Wed, 7 Feb 2018 16:17:11 -0600
Reply-To:
TechNet E-Mail Forum <[log in to unmask]>, Jack Olson <[log in to unmask]>
Subject:
MIME-Version:
1.0
Message-ID:
Content-Type:
text/plain; charset="UTF-8"
Content-Transfer-Encoding:
quoted-printable
From:
Jack Olson <[log in to unmask]>
Parts/Attachments:
text/plain (17 lines)
sorry for the long delay (and thank you for the responses)
but as I was reviewing these posts I had another question:

Have you ever heard of problems with conformal coating material wicking up the connector leads and causing intermittent connections?

thanks again,
Jack


On Wed, 6 Dec 2017 14:09:46 -0500, lduso - Diamond-MT.com <[log in to unmask]> wrote:

(..snip...)
>It's up to me to decide how close to J1 to get with the coating. I once
>coated the leads of all the fine-pitch connectors and the customer said
>that was too close. The next customer will reject the work if I don't coat
>the leads.