TECHNET Archives

January 2012

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Sender:
X-To:
Date:
Mon, 9 Jan 2012 20:59:46 -0600
Reply-To:
TechNet E-Mail Forum <[log in to unmask]>, Gary Bremer <[log in to unmask]>
Subject:
MIME-Version:
1.0
Message-ID:
Content-Type:
text/plain; charset="UTF-8"
Content-Transfer-Encoding:
quoted-printable
From:
Gary Bremer <[log in to unmask]>
Parts/Attachments:
text/plain (16 lines)
I check where else this light was used, when they install his lamp on an FR4 board with RMA solder/flux there is no problem.  Have stated cleaning using 140° Fahrenheit water will know the results tomorrow.  Also found that the leads were being stressed when formed possibility of breaking the glass seal during thermal cycles (lamps are running around 95° to 104° Celsius when energized).  My concern was after this panel was potted if not fully clean residual flux could work its way up the lead to the lamp.  Th lamps are tested prior to assembly and work 100% of the time however they are hot.

Thanks for all your help, this form is great and I have always have gotten great advice.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------



ATOM RSS1 RSS2