Technetters,
I'm wondering is there a rule of thumb for pass/fail acceptance on champagne voids (like one for delta Tg or Au embrittlement)?
We see a fair amount of micro (few microns level) voids on a customer board and they are wondering how they can "push" their IAg board supplier.
X-ray rule isn't going to work as they can not be reliably resolve due to the size.
Thank you very much in advance for constructive responses :-).
Vladimir
SENTEC Testing Laboratory Inc.
11 Canadian Road, Unit 7.
Scarborough, ON M1R 5G1
Tel: (416) 899-1882
Fax: (905) 882-8812
www.sentec.ca
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________