TECHNET Archives

May 1997

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Received:
by ipc.org (Smail3.1.28.1 #2) id m0wSUss-000BjBC; Fri, 16 May 97 16:49 CDT
Content-Type:
text/plain; charset=ISO-8859-1
Old-Return-Path:
Date:
Fri, 16 May 1997 18:02:29 -0400
Precedence:
list
Resent-From:
Cc:
MIME-Version:
1.0
Status:
O
X-Mailing-List:
<[log in to unmask]> archive/latest/12785
X-Status:
X-MSMail-Priority:
Normal
X-Loop:
Return-Path:
<TechNet-request>
TO:
Message-ID:
>From bergdi Fri May 16 16:
50:14 1997
Content-Transfer-Encoding:
7bit
Resent-Message-ID:
<"V-ii71.0.T79.1QDVp"@ipc>
Subject:
From:
"Sid Tryzbiak" <[log in to unmask]>
From [log in to unmask] Mon May 19 10:
21:05 1997
X-Priority:
3
X-Mailer:
Microsoft Internet Mail 4.70.1155
Resent-Sender:
TechNet-request [log in to unmask]
Parts/Attachments:
text/plain (48 lines)


We have an Orbotech Xpert 1700 CAM station from which we are generating
IPC-D-356 (netlist) and NTD (net trace data) files. We then take this data
and use the Everrett Charles ValueGrid software to generate the drill files
required to build the 9090 test fixtures.  We've found that there is an
incompatibility between these two software packages. The end result is a
test fixture with missing test points due to confusion between midpoints
and endpoints of the two software packages.

This problem happens frequently when there are via holes in, or partially
in, a surface mount pad.  The Orbotech software sees the center of the SMT
pad as a midpoint and the via hole in the SMT pad as an endpoint, the
opposite of what I would expect. The ValueGrid software drops the midpoint
and thus the SMT pad and also drops the via hole in the SMT pad because it
assumes that the via is a midpoint. Again the end result is a missing
endpoint.  

Does anyone have this same problem?

Does anyone know of software that can generate the drill files necessary to
build Everrett Charles 9090 test fixtures from raw gerber data without the
problems listed above? 


If so, please contact me.


Sid Tryzbiak
VP Engineering
Continental Circuits, Inc
407-699-5000



  

***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]>   *
* with <subject: subscribe/unsubscribe> and no text in the body.          *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact   *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask]      *
***************************************************************************


ATOM RSS1 RSS2