LEADFREE Archives

January 2005

Leadfree@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Reply To:
(Leadfree Electronics Assembly Forum)
Date:
Thu, 13 Jan 2005 16:30:38 EST
Content-Type:
text/plain
Parts/Attachments:
text/plain (48 lines)
Question: "What would you recommend as "accelerated life test" if not a 
thermal cycling
? Power cycling ? Mechanical test ? Any combination ?
Merci beaucoup, Pascal Guihéneuf"

Answer:
Hello Pascal,
Answering those questions in a general context could be a very long story! 
So, just a few short comments:

1) For thermal cycling of SAC assemblies, I presently use stress/strain 
(hysteresis loop) simulations to optimize test conditions (the goal being to 
accumulate damage in an effective manner).  Optimum profile is actually component 
dependent but there are general trends.

2) Power cycling has, in general, been expensive and of long duration 
(although the cycles can be rapid, which does not allow for efficient damage 
accumulation without optimization of cycling conditions).  Werner can probably comment 
more on running a long power cycling test, a couple of years back.

3) There has been claims that mechanical cycling can be correlated to thermal 
cycling. That may be true if you have a large, global CTE mismatch situation, 
although I have never seen an established correlation of wide enough scope 
that bridges thermal and mechanical cycling results.  One thing that is not 
captured by mechanical cycling is stresses in the joints due to local CTE 
mismatches (between solder itself and the interconnected parts).

With best regards,
Jean-Paul.

__________________________
Jean-Paul Clech
[log in to unmask]
http://jpclech.com/ 

EPSI Inc.
P.O. Box 1522, Montclair, NJ 07042, USA
tel: +1 (973)746-3796
fax: +1 (973)655-0815

-------------------------------------------------------------------------------Leadfee Mail List provided as a service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Leadfree
To temporarily stop/(start) delivery of Leadree for vacation breaks send: SET Leadfree NOMAIL/(MAIL)
Search previous postings at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-------------------------------------------------------------------------------