IPC-600-6012 Archives

July 2006

IPC-600-6012@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Hans Shin <[log in to unmask]>
Reply To:
Date:
Wed, 19 Jul 2006 13:36:31 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (47 lines)
I believe that is an error.  TML should be 1.0%.

Hans Shin
Pacific Testing Laboratories, Inc.
www.pacifictesting.com


-----Original Message-----
From: IPC-600-6012 [mailto:[log in to unmask]]On Behalf Of Menuez,
Pete (IE) @ CIN
Sent: Wednesday, July 19, 2006 1:11 PM
To: [log in to unmask]
Subject: [IPC-600-6012] Outgassing Requirement of IPC 6012


All,

We have historically called out outgassing to ASTM 595 for Total Mass Loss
(TML) and Collected Volatile Condensable Materials (CVCM).  Typical values
are 1.0% TML and .1% CVCM

We want to standardize using paragraph 3.10.1 in 6012 but there's are a
couple problems.

First I believe there is an error in the requirement.  3.10 states TML 0.1%.
I don't know of any materials that will meet that requirement.  The first
question then is "Is this an error in the specification?"

The second question is the testing requirement.  When invoked every lot
would have to be tested - similar to a Group A test.  The second question
then is "Is this meant to be a lot test requirement?"

Thanks in advance.




Pete Menuez
Supplier Quality Engineer
L-3 Communications Cincinnati Electronics
7500 Innovation Way
Mason, Ohio 45040
[log in to unmask]

513-573-6401 Voice
513-573-6767 Fax

ATOM RSS1 RSS2