Check IPC-D-275 Table 3-1 for electrical spacing requirements. There's a
formula, but it depends on whether the trace is internal or external,
what the altitude the product will be used in is, and what the coating is.
IPC-D-275, Design Requirements for Printed Circuit Boards and Printed
Circuit Board Assemblies, is available from IPC's order dept: $30
members/ $60 nonmembers.
Mike Buetow
IPC Technical Staff
2215 Sanders Road
Northbrook, IL 60062
P: 847-509-9700, ext. 335
F: 847-509-9798
[log in to unmask]
On Wed, 7 Aug 1996, R.D. Munger wrote:
> Does the IPC have any publications/charts regarding the minimum copper
> clearance spacing for various voltages? We have a 1500VAC copper trace and
> would like to know the minimum gap required from an ajoining copper land.
>
>
> Thank you.
>
> Dan Munger
> Fermilab
> Batavia, IL USA
> [log in to unmask]
>
> ****************************************************************************