I made a mistake... I meant IPC-2221/2222 where I said IPC-6011/6012 > ---------- > From: Timothy Reeves > Sent: Monday, November 1, 1999 11:00 AM > Subject: Re: MIL SPEC QUESTION > > Have any of the following MIL specs been replaced also? > MIL-STD-275 > MIL-C-14550 > MIL-G-45204 > MIL-P-55110 > MIL-P-28809 > > > MIL-STD-275 has been canceled and replaced by IPC-D-275 (which has > subsequently been replaced by IPC-6011/6012, but I don't think the gov't. > has kept up, and is still on IPC-D-275) > MIL-C-14550 and MIL-G-45204 are active, as far as I can tell. > MIL-P-55110 (now MIL-PRF-55110 has latest revision F), and is canceled for > new designs, although it is still in use) and has been replaced by > MIL-PRF-31032, which hasn't caught on very well. > MIL-P-28809 I had to look up (I'm not familiar with it) It appears to be > canceled with no superseding document. > > Timothy Reeves > ECD Circuit Board Division > 13626 South Freeman Road > Mulino, OR 97042 > [log in to unmask] > (503) 829-9108 (800) 228-8198 FAX (503) 829-5482 > ############################################################## TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c ############################################################## To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body: To subscribe: SUBSCRIBE TECHNET <your full name> To unsubscribe: SIGNOFF TECHNET ############################################################## Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional information. If you need assistance - contact Gayatri Sardeshpande at [log in to unmask] or 847-509-9700 ext.5365 ##############################################################