Anybody familar with interpreting Belcore's ionic contamination standard?

Just got off the phone with someone at alphametals stating that they believe
Belcore has adopted IPC's J001 standard on cleanliness.  The J standard states a
1.56 (10.06) micrograms of Sodium Chloride equivalent per square centimeter
(inch) for assembed PWBs based on the surface area of the board plus components.
Apparently, this is independent of what method (Omega meter, Ionograph, etc.) is
used.

Does anyone else have any input on this?

Todd
847-914-6220

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################

################################################################