The answer to this question is utterly a function of the chemistry of the
bath, and will vary dramatically with different chemistries.

Your chemistry vendors must be REAL happy with you dumping an immersion Tin
bath when it has 100 ppm of Copper in it.  Many baths will tolerate up to
3-4000 ppm of Copper.

Rudy Sedlak
RD Chemical Company

################################################################