It depends on who manufactures your BGA devices, where they get their solder
balls from and most importantly how good is your solder stenciling process....
From what I have seen in my facility, your +/- 0.001" is actually excellent
assuming that your tolerancing is derived statistically and not from standard
deviation data....

Marcelo

        -----Original Message-----
        From:   Eric Christison [SMTP:[log in to unmask]]
        Sent:   Tuesday, October 13, 1998 10:55 AM
        To:     [log in to unmask]
        Subject:        [TN] Tolerance on Collapsed height of BGA Balls

        I am having difficulty in believing something a packaging engineer is
telling me.

        We have a design of sensor which is now BGA packaged. The balls are
0.030" diameter and 0.023" high.
        After reflow I am assured that the collapsed height will be 0.019"
+/-0.001"(given a correctly
        dimensioned footprint) . I have no problem with the 0.019", it's the
+/-0.001" that stretches my
        credibility threshold.

        Is there anyone out there that can confirm or deny this tolerance?

        Regards,




        Eric Christison

        ################################################################
        TechNet E-Mail Forum provided as a free service by IPC using LISTSERV
1.8c
        ################################################################
        To subscribe/unsubscribe, send a message to [log in to unmask] with
following text in the body:
        To subscribe:   SUBSCRIBE TechNet <your full name>
        To unsubscribe:   SIGNOFF TechNet
        ################################################################
        Please visit IPC's web site (http://www.ipc.org) "On-Line Services"
section for additional information.
        For technical support contact Hugo Scaramuzza at [log in to unmask] or
847-509-9700 ext.312
        ################################################################

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################