Mike Bailey wrote:
>
> Try running a weight loss test on your neutralizer after permanganate.
> Depending on the selected chemistry, copper content, temp & dwell time,
> it has the potential to do just that!
>
> ################################################################
> TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
> ################################################################
> To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
> To subscribe:   SUBSCRIBE TechNet <your full name>
> To unsubscribe:   SIGNOFF TechNet
> ################################################################
> Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
> For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
> ################################################################Ed,
Are you using an aggressive glass etch or crust removal step in the permag process?
If you are, then as copper buiilds up in the acid based crust removal step, it will
act as an etch to copper. Chloride based crust removal is more aggressive than
sulfuric acid based.

################################################################