We have received a job that calls for a Mill Max press fit socket (P/N 0279-0-15-01-47-35-10-0) to be pressed into a 17 layer, 135 mil thick printed circuit card. The master drawing package specifies a FHS of .063". The widest dimension of the socket is .067" at the octogon shaped portion of the top 1/3 of the shaft. We were just wondering if anyone has any experience with assembling such devices (i.e., integrity of the PTH, etc). Thanks, Marty W. Sheppard / LYPME Manufacturing Engineering Support (912)-926-9632 DSN 468-9632 Fax: (912)926-7974 email: [log in to unmask] ################################################################ TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c ################################################################ To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body: To subscribe: SUBSCRIBE TechNet <your full name> To unsubscribe: SIGNOFF TechNet ################################################################ Please visit IPC web site (http://jefry.ipc.org/forum.htm) for additional information. For the technical support contact Dmitriy Sklyar at [log in to unmask] or 847-509-9700 ext.311 ################################################################