If you are going to do this test it must be on a substrate that will not change its weight like steel or aluminum. All drum fluxers will spray different amounts of flux. You will find that the amount will vary at the start of a shift due to dry out in the mesh. All drum fluxers are open to air. Bob Willis SMART Group UK Tel: 01245 351502 Fax: 01245 496123