Withdrawn is correct, its content was in it was brought into 6012D (including updated microvia acceptance criteria). 
New designs should not be calling out 6016 any longer. For legacy designs that call out 6016, an agreement between user/supplier should be reached on whether to continue using 6016 (no longer supported by IPC), or to migrate to 6012D for acceptance.


José (Joey) Ríos, Sr QA Engineer
Mission Assurance Manager
Kavli Institute for Astrophysics & Space Research
Massachusetts Institute of Technology
[log in to unmask] <mailto:[log in to unmask]>
(617)324-6272




> On Nov 15, 2017, at 8:27 AM, [log in to unmask] wrote:
> 
> Fellow TechNetters:
> 
>    What is the status of the above stated IPC Standard.   I believe it was WITHDRAWN?
> 
> Victor,