Hi, I have written tons of code to deal with MyData Pick and Place machines. I chose MyData long ago as the MyData file formats are well documented in their "Software Manual". I generated these files from databases I constructed for parts and boards. There are a number of different files, all text files) used to transfer different types of data: .PCK files for Package Data .CMP files for Component Data .PBF files for board placement information .TRT and .TRY for tray type and try information. (I did a lot of work feeding parts on disposable laser cut cardboard trays.) You want to get a software users manual for the version of TPSys that you are using. Bob Kondner -----Original Message----- From: TechNet [mailto:[log in to unmask]] On Behalf Of Gessica Cardozo Sent: Monday, June 12, 2017 7:35 AM To: [log in to unmask] Subject: [TN] Using Pick and place on MYDATA Hello everone, I have a little problem to use Pick N' Plance on MYDATA. I wanna know what is the correct reading file of MYDATA and how this file is structured. Thanks