Jim, There are lots of "it depends" that I could throw at this, but lets start with what you are contractually bound to provide. I would expect at least the ROSE test. Then we can go from there. Doug Pauls "Marsico, James - ES" <[log in to unmask]> Sent by: TechNet <[log in to unmask]> 08/30/2011 01:45 PM Please respond to TechNet E-Mail Forum <[log in to unmask]>; Please respond to "Marsico, James - ES" <[log in to unmask]> To <[log in to unmask]> cc Subject [TN] PWB Cleanliness Hello Technet, I know I should know this, but what cleanliness testing should be performed on CCAs that are soldered with an ORH0 solder paste? What should the acceptance criteria be prior to conformal coating? Thanks in advance, Jim Marsico ITT Corporation 1500 New Horizons Blvd. North Amityville, NY 11701 631-630-5079 [log in to unmask]<mailto:[log in to unmask]> ________________________________ This e-mail and any files transmitted with it may be proprietary and are intended solely for the use of the individual or entity to whom they are addressed. If you have received this e-mail in error please notify the sender. Please note that any views or opinions presented in this e-mail are solely those of the author and do not necessarily represent those of ITT Corporation. The recipient should check this e-mail and any attachments for the presence of viruses. ITT accepts no liability for any damage caused by any virus transmitted by this e-mail. ______________________________________________________________________ This email has been scanned by the MessageLabs Email Security System. For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________ --------------------------------------------------- Technet Mail List provided as a service by IPC using LISTSERV 16.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815 ----------------------------------------------------- ______________________________________________________________________ This email has been scanned by the MessageLabs Email Security System. For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________ --------------------------------------------------- Technet Mail List provided as a service by IPC using LISTSERV 16.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815 -----------------------------------------------------