Ken: Castellated Terminations are addressed in IPC-A-610E at Clause 8.3.4 and J-STD-001E at Clause 7.5.6. Gregg Owens | Sr. Technical Writer Wavestream Corporation (909) 599-9080 x 484 | [log in to unmask] -----Original Message----- From: TechNet [mailto:[log in to unmask]] On Behalf Of Kenneth J. Wood Sent: Tuesday, July 05, 2011 10:14 AM To: [log in to unmask] Subject: [TN] Castellated Hole Acceptability Hi all, I may have asked this a while ago but can't find anything in my emails. Is there an IPC spec that covers castellated hole acceptability? Thanks Ken _____________________________________ Kenneth J. Wood Saturn PCB Design, Inc. www.saturnpcb.com ______________________________________________________________________ This email has been scanned by the MessageLabs Email Security System. For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________ --------------------------------------------------- Technet Mail List provided as a service by IPC using LISTSERV 16.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815 ----------------------------------------------------- ______________________________________________________________________ This email has been scanned by the MessageLabs Email Security System. For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________ --------------------------------------------------- Technet Mail List provided as a service by IPC using LISTSERV 16.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815 -----------------------------------------------------