ROCKY 提到的应该是焊接后产品焊脚结合力的的推力测试吧? 跟应力测试有区别!

 

 

发件人: TGAsia [mailto:[log in to unmask]] 代表 Justin Wu
发送时间: 2011年5月20日 10:04
收件人: [log in to unmask]
主题: Re: [TGAsia] 回流炉中焊接的应力测试

 

可否追溯到相关标准?

 

 

 

 

Thanks and best regards,

Justin Wu

Utilux South China Ltd

Phone: +86-755-2850 7521

Fax:    +86-755-2850 0927

E-mail Address: [log in to unmask]

 

  _____  

From: TGAsia [mailto:[log in to unmask]] On Behalf Of Rocky Wang
Sent: Friday, May 20, 2011 9:32 AM
To: [log in to unmask]
Subject: Re: [TGAsia] 回流炉中焊接的应力测试

 

 

1   0201C   1.2KGF                                                 

2   0201R   1.5KGF


3   0402C   1.5KGF


4   0402R   1.8KGF


5   0603C   2.0KGF


6   0603R   2.2KGF                                                          

7   0805C   2.2KGF                                                          

8   0805R   2.5KGF


9   1206C   2.8KGF


10   1206R   3.0KGF


11   1206 以上阻容元件>3.0KGF


12   MEIF SOF IC ( 8pin )   3.5KGF


13   IC ( 8pin以上)         4.0KGF


14   SOT 23             2.8KGF


15   SOT 14             3.0KGF


 

 

柔性板              

1   0201C     1.5KGF


2   0201R     1.8KGF


3   0402C     2.0KGF


4   0402R     2.2KGF


5   0603C     2.5KGF


6 其余零件均需>2.8KGF。                                                    

 

推力测试条件:

        1. 推力計与PCB面呈45度。

        2. 从元件宽的一面推。

        3. 冷却后测试

 

Best Regards

Rocky

 

From: TGAsia [mailto:[log in to unmask]] On Behalf Of Peng Yunjun
Sent: Thursday, May 19, 2011 9:44 AM
To: [log in to unmask]
Subject: [TGAsia] 回流炉中焊接的应力测试

 

各位老师大家好, 
谁有回流炉中焊接应力的测试方法? 
谢谢分享。 

Peng Yunjun(Mr) 彭云军(先生)
CACC PT Department
[log in to unmask]
+86-431-84684785
13756139127

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________


__________ Information from ESET NOD32 Antivirus, version of virus signature
database 6136 (20110519) __________

The message was checked by ESET NOD32 Antivirus.

http://www.eset.com


__________ Information from ESET NOD32 Antivirus, version of virus signature
database 6136 (20110519) __________

The message was checked by ESET NOD32 Antivirus.

http://www.eset.com



__________ Information from ESET NOD32 Antivirus, version of virus signature
database 6136 (20110519) __________

The message was checked by ESET NOD32 Antivirus.

http://www.eset.com

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________