Is it suppose to be done on coupon or at qualification stage?  Why you
need to do every batch?  If you do, why not have a witness coupon
designed along your production part?  

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Carroll, Thomas A
Sent: Wednesday, September 23, 2009 5:20 PM
To: [log in to unmask]
Subject: [TN] Adhesion Testing of Brush Plating

Fellow Techies,

MIL-STD-865D, Selective, Brush Plating, Electro-Deposition calls for
Adhesion Testing per paragraph 5.5.6e 1 (tape test) or 2 (shot peen).
But I have a supplier telling me that they do not perform the adhesion
test on production application because it would leave a residue.

My question is this:

Do any of you have experience with Selective Brush Plating and if yes,
would you recommend allowing the adhesion test to be waived on
production hardware?

Thanks in advance for your response,
Tom Carroll, CQA, CIT
Supplier Quality Engineer
Boeing Integrated Defense Systems - East Region Supplier Quality

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------------------------
This transmission (including any attachments) may contain confidential information, privileged material (including material protected by the solicitor-client or other applicable privileges), or constitute non-public information. Any use of this information by anyone other than the intended recipient is prohibited. If you have received this transmission in error, please immediately reply to the sender and delete this information from your system. Use, dissemination, distribution, or reproduction of this transmission by unintended recipients is not authorized and may be unlawful.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------